Plugs, Male Threaded Pipe
Open Flow
Pipe
Size Thread
Size Material Max. Pressure Each
NPT Threads
1/8 __ Nickel-Plated Brass 700 psi @ 72° F 9414K62 $5.11
UN/UNF (SAE Straight) Threads
__ 10-32 Nickel-Plated Brass 700 psi @ 72° F 9414K61 4.60
Plugs, Female Threaded Pipe
Open Flow
Thread
Size Material Max. Pressure Each
UN/UNF (SAE Straight) Threads
10-32 Nickel-Plated Brass 700 psi @ 72° F 9414K71 $4.60
Plugs, Barbed Tube
Barbed plugs and sockets insert into tubing and secure with a clamp.
Open Flow
For
Tube ID Material Max. Pressure Each
1/8" Nickel-Plated Brass 700 psi @ 72° F 9414K81 $4.18
5/32" Nickel-Plated Brass 700 psi @ 72° F 9414K82 4.18
3/16" Nickel-Plated Brass 700 psi @ 72° F 9414K83 4.18
Through-Wall Plugs, Barbed Tube
Through-wall plugs and sockets are also known as bulkhead and panel-mount plugs and sockets; they mount through your wall or panel to create an inlet or outlet.
Open Flow
For
Tube ID Material Max. Pressure For Hole
Dia. Range For Max.
Wall Thick. Each
3/32" Nickel-Plated Brass 700 psi @ 72° F 1/4"-5/16" 5/32" 9414K91 $6.03
1/8" Nickel-Plated Brass 700 psi @ 72° F 5/16"-3/8" 7/32" 9414K93 5.67
5/32" Nickel-Plated Brass 700 psi @ 72° F 5/16"-3/8" 7/32" 9414K94 5.67
3/16" Nickel-Plated Brass 700 psi @ 72° F 1/4"-5/16" 5/32" 9414K92 6.03
Sockets, Male Threaded Pipe
Sockets with shut-off have a valve to stop the flow when the coupling is separated, so air won’t leak from your line.
Open Flow
With Shut-Off
Pipe
Size Thread
Size Material Max. Pressure Each Each
NPT Threads
1/8 __ Nickel-Plated Brass 700 psi @ 72° F 9414K12 $11.93 9414K19 $12.18
UN/UNF (SAE Straight) Threads
__ 10-32 Nickel-Plated Brass 700 psi @ 72° F 9414K11 11.43 9414K18 11.68
Sockets, Female Threaded Pipe
Sockets with shut-off have a valve to stop the flow when the coupling is separated, so air won’t leak from your line.
Open Flow
With Shut-Off
Thread
Size Material Max. Pressure Each Each
UN/UNF (SAE Straight) Threads
10-32 Nickel-Plated Brass 700 psi @ 72° F 9414K21 $11.43 9414K28 $11.68
Sockets, Barbed Tube
Sockets with shut-off have a valve to stop the flow when the coupling is separated, so air won’t leak from your line.
Barbed plugs and sockets insert into tubing and secure with a clamp.
Open Flow
With Shut-Off
For
Tube ID Material Max. Pressure Each Each
1/8" Nickel-Plated Brass 700 psi @ 72° F 9414K31 $11.43 9414K36 $11.68
5/32" Nickel-Plated Brass 700 psi @ 72° F 9414K32 11.43 9414K37 11.68
3/16" Nickel-Plated Brass 700 psi @ 72° F 9414K33 11.43 9414K38 11.68
Through-Wall Sockets, Barbed Tube
Sockets with shut-off have a valve to stop the flow when the coupling is separated, so air won’t leak from your line.
Through-wall plugs and sockets are also known as bulkhead and panel-mount plugs and sockets; they mount through your wall or panel to create an inlet or outlet.
Open Flow
With Shut-Off
For
Tube ID Material Max. Pressure For Hole
Dia. Range For Max.
Wall Thick. Each Each
3/32" Nickel-Plated Brass 700 psi @ 72° F 1/4"-5/16" 5/32" 9414K41 $13.78 9414K51 $14.05
1/8" Nickel-Plated Brass 700 psi @ 72° F 5/16"-3/8" 7/32" 9414K43 13.37 9414K53 13.62
5/32" Nickel-Plated Brass 700 psi @ 72° F 5/16"-3/8" 7/32" 9414K44 13.38 9414K54 13.62
3/16" Nickel-Plated Brass 700 psi @ 72° F 1/4"-5/16" 5/32" 9414K42 13.77 9414K52 14.05